• Classic Bollard

    Classic Bollard Prices From £235.50

    The Classic model is designed to be used as an architectural feature in neighbourhoods where the buildings require a more classic design. The collision force needed to bend the bollard to an angle of up to 45 degrees is 360 kilos.

    Enquire

  • Classic Bollard Specification

    Classic Bollard

    MODEL-CLASSIC BOLLARD

    Weight: 39KG
    Bollard overall height: 1350mm
    Bollard diameter below ground: 190mm
    Bollard height above ground: 760mm
    Bollard height below ground: 590mm

    Recommended size for galvanised steel installation pipe:

    205mm diameter x 3.0mm thickness x 640mm height


    Maximum recommended degree bend: Force of 360kg is required to bend to 45%

  • INSTALLATION

    Installation OF Bendy Bollards

    We recommend installing our bollards using a steel pipe.

    The depth of the foundation can be between 1 metre to a minimum of 55 cm where surface conditions allow but only if the impact can be absorbed without the foundation becoming misaligned. If you choose to reduce the depth of the foundation it is important that extra concrete is cast around the pipe to compensate for the shorter length. The more concrete around the pipe the higher the impact force can be absorbed without misaligning the pipe.

    Bollards can be installed in any surface.

    We recommend using steel installation pipe. (Please see table below)

    Installation pipe increases the functioning of the bollard and its flexible strengths.

    • Prepare your foundation (recommended Ø200mm x maximum 1000mm depth)
    • We recommend an opening of approximately 200 mm diameter. The recommended depth for the  foundation is approximately 1000mm but in order to avoid the risk of drilling into wires, pipes or large obstructions it is possible to reduce the depth from 1000mm to a minimum of 550mm, but only if the impact can be absorbed without the foundation becoming misaligned. If you choose to reduce the depth of the foundation it is important that extra concrete is cast around the pipe (see drawing below) to compensate for the shorter length. The more concrete around the pipe the higher the impact force can be absorbed without misaligning the pipe It is imperative that the foundation has a minimum depth to endure the forces of impact and ensure that the bollard will raise to upright position after a collision. 
    • Secure installation pipe in to the foundation.
    • Fill the foundation with gravel/sharp sand to a level that will achieve the required bollard height above the ground.
    • Slot bollard in to installation pipe and secure with sharp sand.

     

     

  • Classic Bollard Photo Gallery

    Classic Black

    Classic Black

    Classic Granite

    Classic Granite

     

     

     

Visit Us

Unit 16, Pipers Ind. Estate, Pipers Lane
Thatcham, Berks, RG19 4NA

Opening Hours

Monday - Friday + 9 AM - 5 PM

TALK TO US

Phone + 01635 861761
Email + This email address is being protected from spambots. You need JavaScript enabled to view it.

Follow Us